BCD
6.0KW SYSTEM SPECIFICATIONS
ELECTRICAL SYSTEM
Starting
Battery
Battery Capacity
Starter
DC No-Load Current
DC Cranking Current
(engine cold)
DC Charger
AC
GENERATOR
General
Voltage
Rating (Volts AC)
60 Hertz
(1800 rpm)
50 Hertz (1500 rpm)
AC Circuit Breaker
Generator Cooling
Air Requirements, (60 Hertz),
at
1800 rpm
Westerbeke
Generators
12-Volt, 26 A-H,
(-)
negative ground
(recommended)
(35
A-H in cold areas)
90 - 125 (Ampere-Hours)
12-Volt,
1.2KW, reduction type,
solenoid-mounted
90 Amp (max.) at 11.5 Volts.
175 - 200 Amps (engine cold)
Integral controller 0 - 10 Amps
13
-14
Volts DC
Brushless, four-pole, revolving field.
Self exciting, capacitor saturated field excitation.
Pre-lubricated, single-bearing design.
Reconnectable
120 Volts
or
120/240 Volts,
single-phase
120
or
120/240 Volts - 60 Hertz
220 Volts - 50 Hertz.
Voltage regulation:
±5%
no load
to
full load.
Frequency regulation: ± 3 Hertz (5%)
no-load
to
full-load.
120 Volts
120/240 Volts
220 Volts
50 Amps
50/25 Amps
20.4 Amps
To be rated at
120%
ofthe
generator's rated
amperage and voltage output.
175 -
200 cfm (4.95 - 5.66 cmm)
16